Santak Rack PDU SBP16GB12-P Power Distribution PDU 16A
The Santak Rack PDU SBP16GB12-P power distribution unit is customized for data center equipment, featuring a 16A rated current supporting 12 national standard sockets. It utilizes integrated solid copper bar conductors and UL94-V0 flame-retardant materials, equipped with a 10KA lightning protection module and aluminum alloy housing, meeting safe power distribution needs for construction sites, laboratories, and data centers, offering flexible horizontal/vertical installation options.
Buy Now
- WeChat:13775032303
- Email:powercube@foxmail.com
Product details
Main content: The Santak PDU SBP16GB12-P power distribution unit is an intelligent power distribution solution specifically designed for rack environments. The product features an integrated high-purity copper bar conductor with a cross-sectional area of 16mm² and resistance below 0.1Ω, reducing energy loss by 30% compared to traditional spliced conductors. The housing is precision-machined from 6063-T5 aluminum alloy via CNC processing, with anodized surface treatment achieving IP40 protection level, effectively preventing equipment leakage and electromagnetic interference. The built-in 10KA surge protection module adopts an MOV+GDT dual-protection architecture with a response time as low as 5ns, capable of withstanding 8/20μs waveform impacts.The output ports are configured with 12 sets of three-flat national standard sockets, featuring 0.8mm thick phosphor bronze spring contacts that maintain a contact resistance of ≤10mΩ even after 5000 insertion/extraction tests. The internal wiring uses 5mm² oxygen-free copper cables certified by VDE, with insulation layers resistant to temperatures up to 150°C, keeping temperature rise below 28°C under full load operation. For installation, it includes 180° rotatable L-shaped mounting brackets, supporting multi-angle adjustment from 0-90°, compatible with 19-inch standard racks. The product is dual-certified by CCC and CE, with a design lifespan of 10 years, making it particularly suitable for demanding scenarios such as IDC server rooms and medical equipment rooms requiring 7×24 uninterrupted operation.
Product Features
- One-piece high-purity copper bar conductor design with 16mm² cross-sectional area, improving conductivity by 18% and effectively reducing energy loss by 30%
- 10KA lightning protection module with built-in MOV+GDT dual protection structure, response time as low as 5ns, capable of withstanding 8/20μs waveform impact
- 6063-T5 aluminum alloy shell with anodizing process, protection level up to IP40, achieving electromagnetic interference shielding and leakage protection
- Phosphor bronze spring socket tested for 5000 insertion/extraction cycles, maintaining stable contact resistance below 10mΩ
- Equipped with 180° rotatable L-shaped mounting plate, supporting 0-90° multi-angle adjustment to meet various standard rack installation requirements
Application Scenarios
- Suitable for 7×24 uninterrupted power supply systems for core equipment in IDC rooms
- Meets power quality requirements for precision imaging equipment such as medical CT machines and MRI
- Adapts to power distribution scenarios for PLC control cabinets in industrial automation production lines
- Provides stable power support for 5G base station communication rack equipment
- Ensures surge-proof power supply needs for high-precision instruments such as laboratory spectrometers
Product Parameters
- Model:SBP16GB12-P
- PDU input rated current:16A
- PDU input voltage range:110~240V
- PDU input rated power:4000W
- PDU input plug:16A national standard plug
- PDU input cable length:2 meters
- PDU input functional module:SPD lightning protection
- PDU output socket type:National standard flat pins
- PDU output rated current:10A
- PDU output socket quantity:12
- Product dimensions:647*44.4*44.4mm
- Installation method:Vertical installation